{"product_id":"cnyst-ac-dc-hipot-tester-and-insulation-resistance-tester-with-measurement-current-0-001ma-20-00ma-resolution-0-001-0-01-discharge-function-5-lcd-touch-panel-rs232-handler-interface","title":"CNYST AC\/DC Hipot Tester and Insulation Resistance Tester with Measurement Current 0.001mA-20.00mA Resolution 0.001\/0.01 Discharge Function 5’’ LCD + Touch Panel RS232\/Handler Interface","description":"\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThis AC\/DC withstand voltage insulation tester is an instrument that integrates multiple testing functions such as electrical strength (AC\/DC withstand voltage) and insulation resistance. It is an important testing equipment for various electrical manufacturers and quality inspection departments.\u003c\/li\u003e\n\u003cli\u003eIt uses a high-speed microprocessor as the control core and can measure various safety and regulatory parameters of the tested object in real-time. It can complete three tests within 4 seconds, especially meeting the requirements of production lines for fast testing.\u003c\/li\u003e\n\u003cli\u003eIt adopts a 5-inch color LCD touch screen, which is easy to operate; Equipped with intelligent upper and lower limit judgment function, it can automatically identify defective products. The entire circuit adopts various anti-interference measures, with strong anti-interference ability. It has both hardware and software protection, greatly improving the reliability of the instrument. Automatic overvoltage and overcurrent protection for safer use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt can provide 5kVAC\/10mA withstand voltage, 6kVDC\/5mA withstand voltage, and insulation resistance 1kv\/50GΩ testing.\u003c\/p\u003e\n\u003cp\u003eControllable sine generator: can be set to operate at 50 or 60Hz during AC output, no longer limited by line voltage;\u003c\/p\u003e\n\u003cp\u003eLinear power amplifier: Low distortion of voltage waveform, simple control, and high reliability.\u003c\/p\u003e\n\u003cp\u003eAnti electric shock protection\/arc detection\/short circuit protection\u003c\/p\u003e\n\u003cp\u003eIt can independently conduct AC withstand voltage test, DC withstand voltage test, and insulation resistance test, and can pass the test\u003c\/p\u003e\n\u003cp\u003eSet up a trial project and conduct sequential testing of multiple projects.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable id=\"ContentPlaceHolder1_tblSpec\" class=\"TechTable\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eMeasurement Functions\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eAC\/DC Withstanding Voltage \u0026amp; IR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eInterface\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eRS232\/Handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eArc Detection\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e9 Levels (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eOther Functions\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eLIST Edit\u003cbr\u003eDischarge Function\u003cbr\u003e5“ LCD + Touch panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e\u003cstrong\u003eAC Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Rate Ouput\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eAC 5.000kV\/10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Voltage\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.050kV-5.000KV AC\u003cbr\u003eResolution: 1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Voltage Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Regulation\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading +5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Frequency\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Measurement Current\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.001mA-20.00mA\u003cbr\u003eResolution: 0.001 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Current Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Rising Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.4s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Testing Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.5s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Falling Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s，OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e\u003cstrong\u003eDC Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e\u003cstrong\u003e●\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Rate Output\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eDC 6kV\/5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Voltage\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.050kV-6.000kV DC\u003cbr\u003eResolution: 10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Voltage Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Regulation\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading +5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Current Measurement\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1μA-10.000mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Current Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading +5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Rising Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.4s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Testing Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.5s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Falling Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Rate Output\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eDC 1kV\/50GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Voltage\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.050kV-1.000kV DC\u003cbr\u003eResolution： 1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Voltage Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e1% of reading + 2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Measurement Range\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e1MΩ-49999MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e220V 50\/60Hz\u003cbr\u003e550VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eDimension \u0026amp; Weight\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e215mm( W )x88mm( H )x400mm ( D )\u003cbr\u003e8kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eAccessories\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eWithstand voltage test line\u003cbr\u003eRS232 Communication\u003cbr\u003eHandler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"CNYST","offers":[{"title":"Default Title","offer_id":52611942154520,"sku":"AT9610-Anbai-Vicky-5","price":1430.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6397\/5192\/files\/1_eda8d426-1cc5-40f6-ad52-3af9714689ff.jpg?v=1788507847","url":"https:\/\/cnystlab.com\/products\/cnyst-ac-dc-hipot-tester-and-insulation-resistance-tester-with-measurement-current-0-001ma-20-00ma-resolution-0-001-0-01-discharge-function-5-lcd-touch-panel-rs232-handler-interface","provider":"CNYST Lab Instruments","version":"1.0","type":"link"}