{"product_id":"cnyst-ac-dc-hipot-tester-digital-ac-dc-withstand-voltage-tester-with-5kvac-10ma-6kvdc-5ma-withstand-voltage-test-output-voltage-0-050kv-5-000kv-ac-0-050kv-6-000kv-dc-resolution-1v-discharge-function","title":"CNYST AC\/DC Hipot Tester Digital AC\/DC Withstand Voltage Tester with 5kVAC\/10mA 6kVDC\/5mA Withstand Voltage Test Output Voltage 0.050kV-5.000KV AC 0.050kV-6.000kV DC Resolution 1V Discharge Function","description":"\u003cp\u003e\u003cstrong\u003eOVERVIEW:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis AC\/DC hipot tester adopts 5 inches TFT true color LCD display ( touch screen) and with high performance 32 bits processor. It is small sizes, light weight 8kg ,super cost-effective, easy to operate. The high-voltage module of the instrument uses a DA as base, a controllable sine generator, a class AB power amplifier, a 40-600Hz high-voltage transformer for boosting, and the output voltage is closed-loop controlled.\u003c\/p\u003e\n\u003cp\u003eThis series equiped with Handler (PLC), The RS232C interface can easily carry out data communication and remote control with the PC, which can meet the reqVERVIEWuirements of automated testing and improve production efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIt can provide 5kVAC\/10mA withstand voltage, 6kVDC\/5mA withstand voltage test.\u003cbr\u003eControllable sine generator: It can be set to work at 50 or 60Hz when AC output, no longer limited by line voltage.\u003c\/li\u003e\n\u003cli\u003eLinear power amplifier: the distortion of the voltage waveform is small, the control is simple and the reliability is high.\u003c\/li\u003e\n\u003cli\u003eOutput voltage closed loop control.\u003c\/li\u003e\n\u003cli\u003eSingle-machine AC withstand voltage test, DC withstand voltage test, and project settings that can pass the test plan, perform multi-item sequential testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TitleDiv\"\u003e\u003cstrong\u003e\u003cspan id=\"ContentPlaceHolder1_TechTitle\" class=\"TitleLabel\"\u003eSPECIFICATIONS:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable id=\"ContentPlaceHolder1_tblSpec\" class=\"TechTable\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eMeasurement Functions\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eAC\/DC Withstanding Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eInterface\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eRS232\/Handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eArc Detection\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e9 Levels (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eOther Functions\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eLIST Edit\u003cbr\u003eDischarge Function\u003cbr\u003e5“ LCD + Touch panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e\u003cstrong\u003eAC Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Rate Ouput\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eAC 5.000kV\/10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Voltage\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.050kV-5.000KV AC\u003cbr\u003eResolution: 1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Voltage Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Regulation\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading +5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Frequency\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Measurement Current\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.001mA-10.00mA\u003cbr\u003eResolution: 0.001 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Current Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Rising Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Testing Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.2s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Falling Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e\u003cstrong\u003eDC Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Rate Output\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eDC 6kV\/5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Voltage\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.050kV-6.000kV DC\u003cbr\u003eResolution: 1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Voltage Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Output Regulation\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading +5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Current Measurement\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1μA-5.000mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Current Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading +5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Rising Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Testing Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.2s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e    Falling Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e110V ~ 220V 47~63Hz\u003cbr\u003e300VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eDimension \u0026amp; Weight\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e270mm( W )x130mm( H )x450mm ( D )\u003cbr\u003e8kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eAccessories\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eHigh voltage test rod\u003cbr\u003eWithstand voltage test line\u003cbr\u003eRS232 Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"CNYST","offers":[{"title":"Default Title","offer_id":52634389578008,"sku":"AT9210A-Anbai-Vicky-2","price":1310.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6397\/5192\/files\/10_7294f2ba-aab6-40a0-ac22-54c04a29e923.jpg?v=1788850763","url":"https:\/\/cnystlab.com\/products\/cnyst-ac-dc-hipot-tester-digital-ac-dc-withstand-voltage-tester-with-5kvac-10ma-6kvdc-5ma-withstand-voltage-test-output-voltage-0-050kv-5-000kv-ac-0-050kv-6-000kv-dc-resolution-1v-discharge-function","provider":"CNYST Lab Instruments","version":"1.0","type":"link"}