{"product_id":"cnyst-ac-dc-hipot-with-insulation-resistance-benchtop-ac-dc-ir-hipot-tester-with-ac-withstand-voltage-rate-ouput-ac-5-000kv-20ma-dc-withstand-voltage-rate-output-dc-6kv-10ma-touch-screen","title":"CNYST AC\/DC Hipot with Insulation Resistance Benchtop AC\/DC\/IR Hipot Tester with AC Withstand Voltage Rate Ouput AC 5.000kV\/20mA DC Withstand Voltage Rate Output DC 6kV\/10mA Touch Screen","description":"\u003cp\u003e\u003cstrong\u003eOVERVIEW:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHT-1310 AC\/DC hipot tester adopts 5 inches TFT true color LCD display ( touch screen) and with high performance 32 bits processor. It is small sizes, light weight 8kg ,super cost-effective, easy to operate. The high-voltage module of the instrument uses a DA as base, a controllable sine generator, a class AB power amplifier, 40-600Hz high-voltage transformer for boosting, and the output voltage is closed-loop controlled.\u003c\/p\u003e\n\u003cp\u003eHT-1310 series equiped with Handler (PLC), The RS232C interface can easily carry out data communication and remote control with the PC, which can meet the requirements of automated testing and improve production efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFEATURES:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eHT-1310 can provide 5kVAC\/20mA withstand voltage, 6kVDC\/10mA withstand voltage, insulation resistance test.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eControllable sine generator: It can be set to work at 50 or 60Hz when AC output, no longer limited by line voltage;\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eLinear power amplifier: the distortion of the voltage waveform is small, the control is simple and the reliability is high.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eOutput voltage closed-loop control: to ensure that the load adjustment rate is small and the test data is reliable.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eIt can independently perform AC withstand voltage test, DC withstand voltage test, and insulation resistance test, and can pass the test\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eProject setting of trial plan, multi-project sequential test.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable id=\"ContentPlaceHolder1_tblSpec\" class=\"TechTable\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eMeasurement Functions\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eAC\/DC Withstanding Voltage \u0026amp; IR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eInterface\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eRS232\/Handler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eArc Detection\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e9 Levels (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eOther Functions\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eLIST Edit\u003cbr\u003eDischarge Function\u003cbr\u003e5“ LCD + Touch panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e\u003cstrong\u003eAC Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eRate Ouput\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eAC 5.000kV\/20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.050kV-5.000KV AC\u003cbr\u003eResolution: 1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eVoltage Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eOutput Regulation\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading +5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eMeasurement Current\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.001mA-20.00mA\u003cbr\u003eResolution: 0.001 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eRising Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eTesting Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eFalling Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e\u003cstrong\u003eDC Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eRate Output\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eDC 6kV\/10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.050kV-6.000kV DC\u003cbr\u003eResolution: 1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eVoltage Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eOutput Regulation\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading +5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eCurrent Measurement\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1μA-10.000mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e2% of reading +5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eRising Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eTesting Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.2s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eFalling Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eRate Output\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eDC 1kV\/10GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.050kV-1.000kV DC\u003cbr\u003eResolution： 1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eVoltage Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e1% of reading + 2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.1MΩ-10GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eIR Accuracy\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e\u0026lt;500V：\u003cbr\u003e0.1MΩ-1GΩ， Accuracy：±(10% of reading +5 digits )\u003cbr\u003e1GΩ-10GΩ , For reference only, no accuracy requirement\u003cbr\u003e≥ 500V：\u003cbr\u003e1MΩ-1GΩ， Accuracy：±（5% of reading +5 digits）\u003cbr\u003e1GΩ-10GΩ， Accuracy：±（10% of reading +5 digits）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eTesting Time\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e0.2s-999.9s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e110VAC~220VAC 47Hz~63Hz 300VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eDimension \u0026amp; Weight\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003e270mm( W )x130mm( H )x450mm ( D )\u003cbr\u003e8kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"FirstCell\"\u003eAccessories\u003c\/td\u003e\n\u003ctd class=\"SecondCell\"\u003eHigh voltage test rod\u003cbr\u003eWithstand voltage test line\u003cbr\u003eRS232 Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"CNYST","offers":[{"title":"Default Title","offer_id":52687621226776,"sku":"AT9220-Anbai-Vicky-4","price":1654.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6397\/5192\/files\/10_b69ddf6c-6c53-4f13-9492-62767508546a.jpg?v=1789538256","url":"https:\/\/cnystlab.com\/products\/cnyst-ac-dc-hipot-with-insulation-resistance-benchtop-ac-dc-ir-hipot-tester-with-ac-withstand-voltage-rate-ouput-ac-5-000kv-20ma-dc-withstand-voltage-rate-output-dc-6kv-10ma-touch-screen","provider":"CNYST Lab Instruments","version":"1.0","type":"link"}