{"product_id":"cnyst-turbidity-meter-handheld-turbidy-meter-with-calibration-liquids-turbidity-accuracy-2-of-reading-0-500-ntu-3-of-reading-501-1000-ntu-resolution-0-01-0-1-1-automatic-calibration-2-to-5-points","title":"CNYST Turbidity Meter Handheld Turbidy Meter  with Calibration Liquids Turbidity Accuracy ±2% of  Reading (0-500 NTU) ±3% of  Reading (501-1000 NTU) Resolution 0.01 0.1 1 Automatic Calibration 2 to 5 Points","description":"\u003cp\u003e\u003cstrong\u003eCNYST Turbidity Meter Handheld Turbidy Meter  with Calibration Liquids Turbidity Accuracy ±2% of  Reading (0-500 NTU) ±3% of  Reading (501-1000 NTU) Resolution 0.01 0.1 1 Automatic Calibration 2 to 5 Points\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAbout this item:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul class=\"a-unordered-list a-vertical a-spacing-mini\"\u003e\n\u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003eEasy-to-use portable turbidity meter Selectable 4 turbidity units, including the NTU, FNU, EBC and ASBC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003eMeasurement Method: ISO 7027 nephelometric method (90°); Range: 0~1100 NTU\/FNU, 0~275 EBC, 0~9999 ASBC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003eResolution: 0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~1100 NTU); Auto-Power Off effectively conserves battery life;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"a-spacing-mini\"\u003e\u003cspan class=\"a-list-item\"\u003eAccuracy: ±2% (0~500 NTU), ±3% (501~1100 NTU); Reset feature automatically resumes all settings back to factory default options.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"a-spacing-mini\"\u003e\n\u003cspan class=\"a-list-item\"\u003eSingle measurement mode automatically recognizes and holds the stable reading; Continuous measurement mode can be used for indexing or matching the sample vials; Expanded memory stores and recalls up to 100 data sets.\u003c\/span\u003e\u003cspan class=\"a-list-item\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"aplus-module-csa-wrapper\" data-csa-c-type=\"widget\" data-csa-c-slot-id=\"aplus-module-3p-module-b-3\" data-csa-c-content-id=\"amzn1.aplus.af5e169b-eaf4-493f-972b-0707c9694ff3:1768899927588.9cbc3155-078d-4a04-8be8-0101857224bc.en_US\" data-csa-c-id=\"4mrnk6-sjadr5-e4bloq-z84lzr\"\u003e\n\u003cdiv class=\"celwidget aplus-module 3p-module-b aplus-standard\" data-cel-widget=\"aplus-3p-module-b\" data-csa-c-id=\"yp43u8-j71epk-fwx2pq-md5cx3\"\u003e\n\u003cdiv class=\"aplus-module-wrapper aplus-3p-fixed-width\"\u003e\n\u003cp class=\"a-spacing-base\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eNotice : The Turbidimeter include 10NTU 200NTU 500NTU 1000NTU Turbidity standards solution Liquid\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"aplus-module-csa-wrapper\" data-csa-c-type=\"widget\" data-csa-c-slot-id=\"aplus-module-launchpad-brand-description-left-4\" data-csa-c-content-id=\"amzn1.aplus.af5e169b-eaf4-493f-972b-0707c9694ff3:1768899927588.ed6ac3ec-3857-4990-a822-89a695b6055e.en_US\" data-csa-c-id=\"mfk189-w663ib-zcst6g-dls0ho\"\u003e\n\u003cdiv class=\"celwidget aplus-module launchpad-brand-description-left aplus-standard\" data-cel-widget=\"aplus-launchpad-brand-description-left\" data-csa-c-id=\"mzo49-uzr056-a9ukq5-trim9v\"\u003e\n\u003cdiv class=\"a-section launchpad-module launchpad-module-brand-description-left\"\u003e\n\u003cdiv class=\"a-section launchpad-text-left-justify\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eFeatures:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003col class=\"a-ordered-list a-vertical\"\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eSelectable 4 turbidity units, including the NTU, FNU, EBC and ASBC.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eSingle measurement mode automatically recognizes and holds the stable reading.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eContinuous measurement mode can be used for indexing or matching the sample vials.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eSetup menu allows setting the 7 parameters, including the number of calibration points,resolution, date and time, etc.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eReset feature automatically resumes all settings back to factory default options.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eStored data can be transferred into computer by USB communication interface\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eTechnical Specifications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"a-unordered-list a-vertical\"\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eMeasurement Method: ISO 7027 nephelometric method (90°)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eRange: 0~1100 NTU\/FNU, 0~275 EBC, 0~9999 ASBC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eResolution: 0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~1100 NTU)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eAccuracy: ±2% (0~500 NTU), ±3% (501~1100 NTU)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eLight Source: Infrared-emitting diode (850nm wavelength)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eDetector: Silicon photodiode\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eStray Light: \u0026lt;0.02 NTU\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eSample Vials: 60(H)×25(Dia.)mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eMeasurement Modes: Single or Continuous measurement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003ePower Off: Manual or Automatic (15 minutes after last key pressed)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eReset Function: Yes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eMemory: Stores up to 100 data sets\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eOutput: USB communication interface\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eDisplay: LCD\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003ePower Requirements: 1×9V\/800mA battery\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003e（Battery not included in the package）\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eSize: 180(L)×85(W)×70(H)mm; Weight: 300g\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"CNYST","offers":[{"title":"Default Title","offer_id":53322370777368,"sku":"TB100-BANTE-Nina-4","price":447.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6397\/5192\/files\/8_ed4596a2-0e05-450d-a7f2-f250f7a4d149.jpg?v=1794905008","url":"https:\/\/cnystlab.com\/products\/cnyst-turbidity-meter-handheld-turbidy-meter-with-calibration-liquids-turbidity-accuracy-2-of-reading-0-500-ntu-3-of-reading-501-1000-ntu-resolution-0-01-0-1-1-automatic-calibration-2-to-5-points","provider":"CNYST Lab Instruments","version":"1.0","type":"link"}