{"product_id":"cnyst-underground-pipeline-detector-digital-underground-utility-cable-locator-with-type-c-usb-interface-air-socket-connection-interface-pipeline-measurement-depth-0-20m-calibrable-cables-1-20","title":"CNYST Underground Pipeline Detector Digital Underground Utility Cable Locator with Type-C USB Interface Air Socket Connection Interface Pipeline Measurement Depth 0-20m Calibrable Cables 1~20","description":"\u003cp\u003e\u003cstrong\u003eCNYST Underground Pipeline Detector Digital Underground Utility Cable Locator with Type-C USB Interface Air Socket Connection Interface Pipeline Measurement Depth 0-20m Calibrable Cables 1~20\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAbout this item:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e★ \u003c\/span\u003eMultiple detection modes: classical positioning mode, wire cruise mode, signal distortion measurement mode\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e★\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eCurrent direction determination (partial frequency), can be calibration current direction, eliminate adjacent line interference, to prevent tracking errors\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003eMultiple detection frequencies: 11 active detection frequencies and 3 passive detection frequencies\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e★\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eTransmitter a variety of signal output: direct output, caliper coupling, induction method\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntroduction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIntelligent Utility detector, also known as Utility locator, Path Locator, is a very comprehensive path detection instrument. It has pipeline path detection, cable identification, fault search and other functions. The instrument is composed of transmitter, transmitting current clamp, receiver, receiving flexible current clamp, connecting test line, A-word frame (optional), etc.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIntelligent Utility detector can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables under trenchless excavation. The instrument uses a variety of filtering technologies, has anti-interference ability, and can accurately locate and measure the depth. It is suitable for the detection and patrol of various underground metal pipeline, pipeline management and maintenance, municipal planning and construction, power supply and other departments, and is one of the necessary instruments of pipeline maintenance units. This function is realized by the signal transmitter, receiver, signal transmitting clamp and connecting test line. The instrument has the following characteristics:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMultiple detection modes: classical positioning mode, wire cruise mode, signal distortion measurement mode;\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eClassic positioning mode: compass, direction and signal amplitude display, visually display the left and right direction of the pipeline。\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead cruise mode: 360 omnidirectional pipeline path indication, continuous display of depth, current, and pipeline relative position. The interface is simple and intuitive, and it can be operated without experience\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSignal distortion measurement mode: the peak and trough wave form should be displayed at the same time. In the field without distortion, the peak and valley value position should be consistent, and the field shape should be symmetrical relative to the centrol line.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCurrent direction determination (partial frequency), can be calibration current direction, eliminate adjacent line interference, to prevent tracking errors.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFull digital high-precision sampling processing: stable and reliable, ultra-high sensitivity, extremely narrow reception frequency band, strong anti-interference ability, can fully inhibit the power frequency and harmonic interference of adjacent running cables and pipelines.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMultiple detection frequencies: 11active detection frequencies and 3 passive detection frequencies.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTransmitter a variety of signal output: direct output, caliper coupling, induction method.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTransmitter digital amplifier power output, automatic impedance matching, automatic protection.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCable identification is designed for power cable engineers and cable workers to solve the technical problems of cable identification. It can be used to identify live and blackout cables. The user can accurately identify one of the target cables from multiple cables through the instrument to avoid serious accidents caused by mistaking live cables. For cable identification, 20 cables can be pre-calibrated at the transmitter and then received and identified at the remote end, which greatly saves the time of engineering personnel to and from calibration operation and improves work efficiency. The cable identification is successfully marked with √, and the non-target cable is marked with ×, which can quickly and automatically identify the target cable. The function is realized by the cooperation of signal transmitter, receiver, signal transmitting clamp, connecting test line and flexible caliper.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSignal transmitter: used for pipeline path detection and cable identification. The device can add identification signals to the target cable through direct connection output, caliper coupling, induction method, and other methods. There are 11 different pulse signals of 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7 kHz, 65.6 kHz, 81.9 kHz, and 197 kHz. The maximum signal output power is 15W, and 6 levels are adjustable, adapting to different application environments, making pipeline detection and cable identification more accurate and reliable. Instrument built-in large function rate can be charged with lithium battery, automatic impedance matching, automatic protection. The transmitter adopts the integrated special toolbox design, its box can withstand the pressure of about 200kg, the host 5 inches of the capacity touch LCD display, real-time dynamic display signal output status and battery usage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTransmitter clamp: suitable for caliper coupling method. The transmitter clamp couples the signal emitted by the transmitter to the target cable, and the jaw size is Φ125mm. The transmitter clamp is directional, and the transmitted signal flows in from the direction indicated by the arrow on the transmitter clamp.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReceiver: Used for pipeline path detection and cable identification. Built-in multiple shielded 3D antennas, It can effectively identify 13 different pulse coded current signals of 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz and 197kHz generated by the transmitter. It can also identify 50Hz and 60Hz power frequency signals and RF signals with center frequencies of 32.7kHz and 81.9kHz. Using 4.3 inch capacitive touch LCD screen, real-time dynamic display 360° omnidirectional pipeline path indication, depth, current and relative position of the pipeline.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFlexible current clamp: Used for cable identification. The current clamp is a Roche coil, which has excellent transient tracking ability, can quickly identify the pulse width frequency signal generated by the transmitter, and is suitable for thick cables or irregularly shaped conductors. The inner diameter of the clamp is about 200mm, which can clamp the cable below Φ200mm, without disconnecting the measured line, non-contact measurement, safe and fast.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSpecial note: When the power failure cable is identified: it is strictly prohibited to access the live cable. Live cable identification is only applicable to three-core armored cables. In recognition, the transmitter clamp and the receiver clamp can not be mixed, and the direction of the input signal should be consistent.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Calibri;\"\u003ePRODUCT INTRODUCTION:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eUnderground Utilities Locator, also known as Utility locator, Path Locator, is a very comprehensive path detection instrument. It has pipeline path detection, cable identification, fault search and other functions. The instrument is composed of transmitter, transmitting current clamp, receiver, receiving flexible current clamp, connecting test line, A-word frame (optional), etc.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eUnderground Utilities Locator can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables under trenchless excavation. The instrument uses a variety of filtering technologies, has anti-interference ability, and can accurately locate and measure the depth. It is suitable for the detection and patrol of various underground metal pipeline, pipeline management and maintenance, municipal planning and construction, power supply and other departments, and is one of the necessary instruments of pipeline maintenance units. This function is realized by the signal transmitter, receiver, signal transmitting clamp and connecting test line.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTECHNICAL PARAMETERS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003e1. Receiver specifications\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable class=\"MsoNormalTable\" border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eUtility detector (cable position tracking, direction display, depth measurement, current measurement), cable identification, A-frame fault detection (optional function)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e8.4V large capacity rechargeable lithium battery\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eInput mode\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eBuilt-in receiving coil, flexible caliper, A-frame (optional function)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eReceive frequency\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eActive detection frequency: 640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz, 197kHz\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003ePower frequency passive detection frequency: 50Hz, 60Hz, 250Hz\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eRF passive detection frequency band: the central frequency is divided into: 32.7kHz, 65.6kHz, 81.9kHz, 197kHz\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eUtility detector modes\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eWide peak method, narrow peak method, sound valley method\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eUtility detector display modes\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eClassic positioning mode, wire cruise mode, signal distortion measurement mode\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eUtility detection Scope of detection\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eDirect connection method: generally can reach the cable length of 0~20 kilometers, mainly determined by the grounding resistance, cable resistance and cable buried depth\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eCoupling method: generally can reach the length of the cable 0~10 kilometers, mainly determined by the grounding resistance, cable resistance and cable buried depth\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eInduction method: suitable for cables with buried depth less than 2m\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eDepth and current\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eDisplay the cable depth and current value in real time\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePipeline measurement depth\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e0-20m\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eDeep precision\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eFlat position precision accuracy: Central axis position of the target cable or pipeline: ± 5% (buried depth in 0-3m) -10% (buried depth in 3m-20m)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePositive and wrong prompt\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eExcluding the interference of adjacent cables, in the measurement of adjacent cables, the measurement of the adjacent cables can be distinguished according to the different signal strength and the measured current phase of the adjacent cables. In the process of tracking the cables, the phase dial and pointer can be observed to distinguish the measured cables and the adjacent cables\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eSound instructions\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eFM tone with signal intensity\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eCapacity of resisting disturbance\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eVery narrow receiving frequency band and unique digital processing method can fully suppress the power frequency and harmonic interference of adjacent operating cables and pipelines\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eCable identification\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eIdentification mode: flexible caliper intelligent identification; Number of calibrable cables: 1~20;\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eCalibration value: the current percentage of the received signal and the transmitted signal between 75% and 135% of the calibration value is one of the conditions for successful identification;\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eDirectionality: the transmitter clamp, receiver clamp must be in the same direction as the loading signal, which is one of the conditions for successful identification\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eCable identification Range of detection\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eDirect connection method: can identify the signal with a circuit resistance of 0 Ω ~ 8 kΩ (generally, the length of the cable can reach 0~20 km, mainly determined by the grounding resistance and cable resistance)\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eCoupling method: can identify the signal with circuit resistance of 0 Ω ~ 1 kΩ; (generally the cable length is 0~6 km, mainly determined by the grounding resistance and cable resistance)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eSize\/Weight\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e350mm(length) × 155mm(width) × 700mm(high), around 2kg\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eConnection interface\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eType-C USB interface, air socket\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eCoil inner diameter\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003eΦ200mm (A larger caliber can be customized as needed)\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"254\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eSuitable for safety regulations\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"578\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eIEC61010-1 CAT III 600V, IEC61010-031, IEC61326, Pollution grade 2\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan\u003e2. Transmitter specifications\u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"274\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eMultiple frequency signal transmission modes\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e10.8V Large-capacity rechargeable lithium battery\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eOutput method\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eDirect connection method, caliper coupling method, induction method\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eOutput mode\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAutomatic identification, according to different accessories\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eOutput frequency\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e640Hz, 1.28kHz, 2.56kHz, 3.20kHz, 4.09kHz, 8.19kHz, 10.2kHz, 32.7kHz, 65.6kHz, 81.9kHz, 197kHz\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eOutput power\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e15 W max, The 9 gear adjustable\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eImpedance\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eAutomatic real-time impedance matching and protection function\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eDirect output voltage\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e150Vpp max\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eInstrument size\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e320mm(Length) × 275mm(Width) × 145mm(High)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eTransmitter about 3.85kg; The transmitter clamp is about 1.18kg\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eLaunch clamp inner diameter\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003eφ125mm\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eLength of transmitter clamp\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003e3m\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eP-wire\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eRed test cable 3m, black test cable 3m\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eConnection interface\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eUSB interface, DC interface, aviation socket\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eElectromagnetic characteristics\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eIEC61326(EMC)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eSuitable for safety regulations\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eIEC61010-1 (CAT III 300V, CAT IV 150V, class of pollution 2)\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\" align=\"center\"\u003e\u003cspan\u003eIP\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"509\" valign=\"center\"\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan\u003eIP45\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"CNYST","offers":[{"title":"Default Title","offer_id":53070037090584,"sku":"ES7080-Zhengneng-Vicky-6","price":4030.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6397\/5192\/files\/61NpIoX56oL._SL1000_107d5c87-7aa4-4de9-afd9-c872a39e2127.jpg?v=1793173495","url":"https:\/\/cnystlab.com\/products\/cnyst-underground-pipeline-detector-digital-underground-utility-cable-locator-with-type-c-usb-interface-air-socket-connection-interface-pipeline-measurement-depth-0-20m-calibrable-cables-1-20","provider":"CNYST Lab Instruments","version":"1.0","type":"link"}