CNYST Portable Through Coating Ultrasonic Thickness Gauge Ultrasonic Thickness Testing Equipment with A-scan And B-scan Function Measurement Range 1.2-200mm Coating Mode Measurement Range 3-50mm

About this item:

  • Working principle: Pulse echo with dual element transducers; Resolution: Selectable 0.01mm,0.1mm( 0.001",0.01"); Display Mode: Normal, Minimum / Maximum capture, DIFF/RR%
  • 2.4 Color OLED, 320×240 Pixels Display, Live Time A-Scan and Thickness Display, Time-based B-Scan Display; Echo-Echo Mode(Thru Paint & Coatings),Stores 100,000 Measurement Values and 1000 waveforms, etc.
  • Measuring Range: 0.5 to 508mm(0.02" to 20.00"), depending on probe,material and surface condition; Velocity Range: 500~9999m/s, 0.0197~0.3937in/us; Repeatability: ±0.05mm; Auto Shut-off: After 5,10,20 minutes of non-action period
  • Measuring Error: ±0.05mm (25mm below); ±0.2% H (100mm above); ±0.5% H (100mm above); H is the height of testing object; Auto Shut-off: After 5,10,20 minutes of non-action period
  • A/b-Scan Ultrasonic Thickness Gauges is used for measuring the thickness of metal materials, pipes, pressure vessels, sheet metals (steel, aluminum), plastic, steel pipes, PVC pipes, glass and other materials. Also be widely used in manufacturing, metal processing industry, chemical industry, industry inspection and testing field.

Shipping Policy : Battery not included during the shipping

Application:

A/b-Scan Ultrasonic Thickness Gauges is used for measuring the thickness of metal materials, pipes, pressure vessels, sheet metals (steel, aluminum), plastic, steel pipes, PVC pipes, glass and other materials. Also be widely used in manufacturing, metal processing industry, chemical industry, industry inspection and testing field.

Brief Introduction:

2.4 Color OLED, 320×240 Pixels Display, Live Time A-Scan and Thickness Display, Time-based B-Scan Display, Echo-Echo Mode(Thru Paint & Coatings), Stores 100,000 Measurement Values and 1000 waveforms, etc.

Technical Specifications

Working principle: Pulse echo with dual element transducers

Measuring Range: Standard mode: 0.5 to 508mm (0.02" to 20.00"); coating mode: substrate thickness 3.0--50mm, depending on probe,material and surface condition

Resolution: Selectable 0.01mm,0.1mm( 0.001",0.01")

Probe Calibration: One-Point Calibration, Two-Point Calibration

Measuring Error: ±0.05mm (25mm below); ±0.2% H (100mm above); ±0.5% H (100mm above); H is the height of testing object

Measurement Update Rate: Selectable 4Hz, 8Hz, 16Hz

Velocity Range: 500~9999m/s, 0.0197~0.3937in/us

Repeatability: ±0.05mm

Display Mode: Normal, Minimum / Maximum capture, DIFF/RR%

V- Path Correction: Automatic

Alarm Settings: Minimum and Maximum alarms.Dynamic waveform color change on alarm

Capacity: 100,000 readings, 1000 waveforms, 400 files

Power Supply: Two 1.5V AA batteries(Battery not included in the package)

Size: 153mm×76mm×37mm (H×W×D)

Standard Configuration: Ultrasonic Thickness Gauge,Standard Probe( Standard probe range 1.2-200mm),Instrument Case,Operating Manual, Certification

Complementary products

    Customers also bought