CNYST Digital Ultrasonic Through Coating Thickness Gauge with Repeatability 0.05mm PT-08 Probe Standard Mode Measurement Range 0.8mm~100mm Coating Mode Measurement Range 3mm~20mm P-E Method E-E Method

About this item:

  • Operating Principle: P-E (pulse-echo), E-E (echo-echo) with dual-crystal probes; Measuring Range : Standard mode: 1mm to 100mm, depending on material and probes Thru coating mode: 3mm to 20mm with PT-08 probe
  • Resolution: 0.01mm / 0.001in ; Repeatability: ±0.05mm/0.002in; V-Path Correction:Automatic ; has through coating function.
  • Display: 128×64 dot-matrix LCD screen with EL backlight, Auto shut-off: after 5 minutes of non-use
  • Material Velocity Range: 1000~9999m/s or 0.0394~0.3937in/us; Measurement Update Rate: 4Hz in standard measurement mode
  • Ultrasonic thickness gauges is used for measuring Metal and Nonmetal Materials, include Plastic thickness measurement, Steel/Pipe thickness measurement, PVC thickness measurement and Glass Plates thickness measurement,etc.

Shipping Policy : Battery not included during the shipping

Application:

Ultrasonic thickness gauges is used for measuring Metal and Nonmetal Materials, include Plastic thickness measurement, Steel/Pipe thickness measurement, PVC thickness measurement and Glass Plates thickness measurement,etc. has through coating function.

Technical Specifications

Display Screen: 128×64 Dot Matrix LCD Display (EL Backlight)

Working Principle: Using dual crystal probe pulse-echo method, echo-echo method

Standard Mode Measurement Range: 0.8mm~300mm (depending on the probe and the material being measured)

PT-08 is standard probe with measuring range from 0.8mm to 100mm.

Coating Mode Measurement Range: 3mm~20mm (using standard probe)

Measurement Lower Limit for Pipe Materials (Steel): φ20mm×3.0mm (standard probe), φ15mm×2.0mm (small diameter tube probe), measurement error ≤ ±0.1mm.

Measurement Error: ±0.05mm (H<10mm) ±(0.5%H+0.01) (H≥10mm)Note: H is the actual thickness of the measured object

Repeatability:0.05mm

Measurement Resolution:0.01mm or 0.001in

Unit:Millimeter or Inch

Calibration Mode: Quick Calibration, Two-Point Calibration

V Path Correction: Automatic V sound path correction, compensating for the non-linearity of the dual crystal probe

Measurement Update Rate: 4Hz

Material Sound Speed Range: 1000~9999 m/s or 0.0394~0.3937 in/us

Storage Function: Divided into 5 arrays, can store 500 thickness values

Minimum Value Capture: Refers to capturing the minimum value in the measurement process

Alarm Function: Can set thickness limits, with alarm sound for measurements outside the limits

Sound Speed Storage: Can store sound speeds for 5 different materials

Working Language: Can choose Chinese, English

Communication Interface: USB interface or RS232 serial port (optional)

Power Supply: Two 1.5V AA batteries, with low voltage prompt when power is insufficient(Battery not included during the shipping)

Operating Time: Alkaline batteries can be used for 200 hours (without backlight)

Automatic Shutdown: Automatically shuts down after 5 minutes of inactivity

Working Temperature: -10C~+50℃

Size: 149mm×73mm×32mm (H×W×D)

Weight: 210g (including battery)